Illustrative U-tube anti-roll response and a single-tank tuned-absorber comparison.
An invented, illustrative U-tube system comprises two tank legs connected by a conduit. Analysis is performed to determine the connected-tank response and compare it with a single-tank tuned absorber. The geometry represents no particular vessel or client. The results are summarized below.
Analytical predictions are evaluated using the connected-tank model and the tuned-absorber model, with published aggregate calibration results. Archived computational fluid dynamics (CFD) evidence is presented separately from the illustrative predictions. The predictions support screening; design qualification is not established.
The published moment-fit band limits the use of the aggregate error statistic. Transfer to the invented geometry remains an assumption, including inside that band. The single-tank comparison illustrates peak splitting and merging; its amplitudes do not establish a design ranking.
Related: generic hull roll screening estimate.
Draft for maintainer review.
| Revision | Date | What changed and why |
|---|---|---|
| Related pages | 2026-10-27 | Link to the generic hull roll screening estimate added for related anti-roll context. |
| Display precision | 2026-10-23 | Damping-axis labels distinguished and comparison percentages rounded to one decimal place; source precision retained in the evidence record. |
| Evidence | 2026-10-23 | Archived CFD reductions added with provenance and evidence-class limits to distinguish measurements from illustrative predictions. |
| Geometry | 2026-10-23 | Independent illustrative dimensions and conduit area selected to separate the predictions from the reference geometry. |
| Editorial | Not assigned | Engineering descriptions clarified to distinguish illustrative predictions from calibration evidence. |
| Initial | Not assigned | Public-source analysis added to document model scope and remaining work. |
Invented round dimensions are selected independently of the published reference geometry. Validation of the illustrative plan areas and centroid offset is not established. Fill depth is an input; a validated fill-percentage range is not established.
| Input | Illustrative value | Source and assumption |
|---|---|---|
| Each leg length × width | 30.0 × 8.0 m | Independent invented round dimensions |
| Each leg plan area | 240.0 m² | Product of the illustrative leg length and width |
| Leg centroid offset from centreline | 10.0 m | Independent invented round offset |
| Fill depth | 4.0 m | Independent invented round depth |
| Conduit area for period sweeps | 8.0 m² | Independent invented area within the published conduit-area input range |
| Effective conduit length | 5.2 m | Calibrated reference value from the connected-tank model; transfer is assumed |
| Published conduit-area input range | 3.4–13.5 m² | Reference period inputs; individual CFD measurements are not reproduced |
The illustrative conduit area lies inside the published input range in the table. The calibrated effective length is transferred as an assumption; a measured natural period for the new geometry is required before predictive use, as described in the model calibration basis.
The calibration quantities below are reported in the model calibration summary and published calibration checks. RMS denotes root mean square error; each percentage applies to the corresponding reference fit.
| Published quantity | Value |
|---|---|
| Quadratic conduit loss: calibrated area exponent | 2.138 |
| Calibration cases (aggregate results only) | 35 |
| Calibrated loss-law RMS (%) | 8.6 |
| Refitted linear-in-area law RMS (%) | 36.5 |
| Closed-form moment RMS (%) | 4.3 |
| Moment fit applies from forcing period (s) | 20 |
| Degradation reported below about (s) | 16 |
| Effective-length inflation from forced-sweep peak (times) | 2.76 |
The loss comparison is based on a separate refit of each area law, as documented in the calibration checks. A fixed-coefficient exponent substitution is excluded. Effective conduit length is calibrated against a measured natural period, as specified in the calibration basis; the forced-sweep peak is loss-controlled and varies with roll amplitude.
The connected-tank curves are evaluated using the analytical model at the illustrative inputs listed above. Frozen-fluid prismatic roll inertia is calculated in the inertia curve; a validation error for rigid-column conduit inertia is not established by that curve.
Damping is evaluated at forcing period 20.0 s with imposed level-difference amplitudes from the published damping inputs. The calculated damping depends on amplitude; it is not a fixed tank property.
The moment is calculated at 5.0° imposed roll and the illustrative conduit area, using the tank-moment model.
The coupled response is evaluated with the published response inputs: vessel roll period 20.0 s, hull damping 5.0 % and tank authority 12.0 %. Tank authority denotes a normalized stiffness scale, distinct from a mass ratio. In the coupled-response model, the forcing reference is fixed by the bare-vessel roll amplitude. The calculated response is roll per unit wave moment at that finite reference; quadratic loss makes it amplitude-dependent. Shading marks periods outside the published moment-fit band. Wave-spectrum and dimensional vessel calibration are not established.
The tuned-absorber model is evaluated at the frequency grid and damping values in the published response record. The mass ratio, denoted by μ, is 0.05; the frequency tuning ratio is 1.0. A single equivalent tank is coupled to an undamped primary vessel. The tank is not isolated, and its geometry is not matched to the U-tube system. Different normalizations and hull damping are used in the two models; their response amplitudes do not establish a design ranking.
| Tank damping (%) | Resolved peaks | Peak normalized roll |
|---|---|---|
| 3.0 | 2 | 24.1 |
| 9.5 | 2 | 9.9 |
| 12.7 | 2 | 8.9 |
| 18.0 | 1 | 9.2 |
| 30.5 | 1 | 13.5 |
Two peaks are resolved in the light-damping curves; they merge as damping increases, and the peak rises again at the highest damping shown in the table. These curves are evaluated using the single-tank model and the published response record. New connected-tank CFD results are not included. The connected-tank curves are presented separately; a matched single-tank and connected-tank comparison is not established.
The moment model degrades below about 16 s and the CAUSE IS NOT ESTABLISHED. An earlier explanation was withdrawn. The residual also depends on roll amplitude.
The reported moment RMS applies at forcing periods of 20 s or longer for the published calibration. Intermediate periods are not qualified by that aggregate statistic. Even inside the band, transfer to the invented geometry is an assumption. No new physical mechanism is proposed.
The CFD cases belong to an earlier, archived campaign on a twin-tank geometry that is not shown. That geometry is separate from the invented illustrative geometry above. These CFD results were not produced for this page. The evidence record identifies the source reduction, field and digest for each value. Raw fields and geometry are excluded.
Exchange amplitudes are compared at forcing period 6.25 s and imposed roll 5.0°. Ratios are normalized to the smallest area. The historical analytical amplitude uses geometric conduit length; it is not the later calibrated model.
| Area (m²) | CFD amplitude (m³) | Analytical amplitude (m³) | CFD ratio | Analytical ratio |
|---|---|---|---|---|
| 3.4 | 7.9 | 5.9 | 1.000 | 1.000 |
| 6.8 | 16.3 | 12.2 | 2.062 | 2.056 |
| 13.5 | 34.6 | 25.6 | 4.377 | 4.322 |
Exchange-amplitude comparison; ratios retain the archived precision.
| Area (m²) | CFD-derived natural period (s) | Calibrated prediction (s) | Historical geometric-length prediction (s) |
|---|---|---|---|
| 3.4 | 19.3 | 19.7 | 27.0 |
| 6.8 | 14.3 | 14.3 | 19.4 |
| 13.5 | 11.0 | 10.6 | 14.1 |
Period bases differ: the historical period is analytical, not a CFD measurement. The middle area is the calibration reference.
The archive publishes a ±3 % band for the inertia law using one calibrated effective conduit length. The reductions below include an exception: the low-fill check exceeds that band. The error is prediction minus CFD-derived period, divided by CFD-derived period. This checks exchange-mode inertia through natural period; it does not validate frozen-fluid roll inertia. The calibration period is 14.31 s against 14.31 s from the reduction; it is not an independent check.
| Area (m²) | Fill (%) | Prediction (s) | CFD-derived (s) | Error (%) | Band comparison |
|---|---|---|---|---|---|
| 3.4 | 50 | 19.7 | 19.3 | 2.4 | Inside |
| 13.5 | 50 | 10.6 | 11.0 | -3.0 | Inside |
| 6.8 | 25 | 14.0 | 13.5 | 3.7 | Outside: exception |
| 6.8 | 70 | 14.6 | 14.4 | 1.4 | Inside |
| 9.5 | 50 | 12.3 | 12.4 | -0.8 | Inside |
All archived off-calibration period checks; the independent intermediate-area check is included.
Discrete low and high fill checks bracket the calibration fill; continuous fill coverage is not established. Equivalent damping depends on forcing period and imposed roll. The table retains each available condition; the damping chart selects the lower-roll case nearest each predicted natural period.
| Fill (%) | Area (m²) | Forcing period (s) | Roll (°) | Equivalent damping ratio |
|---|---|---|---|---|
| 25 | 6.8 | 12.0 | 5.0 | 0.509 |
| 25 | 6.8 | 13.9 | 5.0 | 0.514 |
| 25 | 6.8 | 16.0 | 5.0 | 0.469 |
| 25 | 6.8 | 13.9 | 10.0 | 0.731 |
| 70 | 6.8 | 13.0 | 5.0 | 0.540 |
| 70 | 6.8 | 14.6 | 5.0 | 0.536 |
| 70 | 6.8 | 17.0 | 5.0 | 0.553 |
| 70 | 6.8 | 14.6 | 10.0 | 0.720 |
Fill-dependent damping at the archived forcing conditions; period predictions and measurements appear above.
The fitted area exponent is n = 2.138, with 8.6 % RMS over 35 cases. The naive inverse-area form has 36.5 % RMS after its own coefficient refit: it underpredicts damping at the smallest area (group RMS 55.1 %) and overpredicts at the largest (group RMS 108.3 %). These group RMS magnitudes are distinct from signed individual errors.
| Area (m²) | Fill (%) | Forcing period (s) | Roll (°) | CFD-derived damping | Original inverse-area damping |
|---|---|---|---|---|---|
| 3.4 | 50 | 19.7 | 5.0 | 0.775 | 0.358 |
| 9.5 | 50 | 12.3 | 5.0 | 0.441 | 0.559 |
| 13.5 | 50 | 10.6 | 5.0 | 0.338 | 0.672 |
Conditions near each predicted natural period. The original inverse-area prediction uses the reference calibration, not the separate all-data coefficient refit.
At the independent intermediate area, the existing law evaluated without refitting gives 8.7 % RMS. Including that area in the fit gives n = 2.112 and 8.7 % RMS over 38 cases. Percentages are rounded to one decimal place; the evidence record retains the source precision. The independent prediction and all-data refit are separate checks.
The medium-mesh forced-roll cases are accepted for screening after cycle convergence. The exchange plateau is separate from the exchange natural period. Fine-mesh confirmation applies at the selected period only; it does not establish convergence throughout the sweep.
| Forcing period (s) | Exchange amplitude (m³) | Roll-moment amplitude (N m) |
|---|---|---|
| 16 | 114.2 | 7473614.6 |
| 18 | 123.3 | 8433125.4 |
| 20 | 129.6 | 9103025.1 |
| 22 | 132.4 | 9497852.5 |
| 24 | 132.4 | 9673479.6 |
| 26 | 130.2 | 9683196.3 |
Completed, cycle-converged medium-mesh sweep.
| Numerical check | Result |
|---|---|
| Fine confirmation period (s) | 24 |
| Exchange change (%) | 0.8 |
| Moment change (%) | 1.5 |
| Fine transient maximum Courant / nominal target | 0.549 / 0.5 |
| Free-decay frequency error (%) | 0.3–0.3 |
| Observed Richardson order | 0.191 |
| Indicative fine-grid GCI (%) | 0.1 |
Fine-mesh Courant exceeds the nominal target. Free-decay convergence is non-asymptotic; the GCI is indicative. Free-decay validates frequency in its own case family, not twin-tank anti-roll response.
Analytical screening cases are not CFD solves. Failed wrappers and open transfer are rejected. Short transfer checks are verification only. Trustworthy phase and anti-roll benefit remain withheld.
| Evidence class | Result family | Disposition | Finding | Limitation |
|---|---|---|---|---|
| CFD no roll | free decay convergence | accepted for frequency validation | 7/7 completed; measured 0.755580-0.755807 Hz vs 0.758054 Hz analytical; 0.3-0.3 % error | Observed Richardson order 0.191; GCI 0.1 % is indicative because convergence is non-asymptotic |
| CFD forced roll | period refinement | accepted for screening | 6/6 medium ten-cycle cases completed and cycle-converged; broad exchange plateau at 22-24 s | Source-neutral twin-tank idealization; not a full vessel/tank structural-load model |
| CFD forced roll | fine confirmation | accepted for screening | 24 s fine case completed; medium-to-fine change 0.8 % exchange and 1.5 % roll moment | Fine transient max Courant 0.549 exceeded nominal 0.5 target |
| CFD transfer | closed and coupled verification | verification only | Closed-outlet and coupled-roll checks completed | Short-duration checks are not periodic-response evidence |
| CFD transfer | open transfer | rejected | Stopped at 0.682764 s without End marker | Unphysical boundary-flux growth; exclude from conclusions |
| CFD matrix | nine selected cases | rejected | 0/9 wrapper cases succeeded | Generated inputs are not CFD results |
| Analytical screening | screening manifest | methodology only | 144/144 analytical cases valid with zero reported mass residual | Not 144 CFD solutions |
| Reduced order | normalization and response algorithms | methodology only | Useful trend screening and normalization collapse | Not direct validation of the resolved twin-tank CFD |
| Reduced order | anti roll phase assessment | withheld | Kinematic magnitudes may be individually consistent | Inertia-free model cannot establish trustworthy phase or anti-roll benefit |
The source-neutral review controls the evidence classification; methodology and validation are not interchangeable.
Further assessment is required before the illustrative response is applied to a design. The geometry assumptions, comparison limits and calibration limits define the outstanding work below.
The archived period checks do not establish a direct frozen-fluid roll-inertia error bound. Raw CFD fields, meshes, unstaged case quantities and the archived geometry are omitted. Continuous fill coverage, matched single-tank versus connected-tank performance, and anti-roll phase or benefit remain unestablished. The earlier campaign does not qualify the invented illustrative geometry.
The analytical scope is described in the sloshing study. The connected-tank calculations and aggregate calibration statistics are defined in the analytical model and published calibration checks. The single-tank comparison is defined in the tuned-absorber model and response record.